Steam Sterilizer LAC-5065SP

 

LAC-5065SP

Steam Sterilizer

Class B Sterilization. Pre & Post Vacuum system

Feature

Pre-vacuum and post vacuum Drying system
Pre-vacuum for effective air removal that results in increasing sterilization performance.
Post-vacuum for drying with remaining system removal

Microprocessor PID program controller with self auto-tuned and LCD display
3 pre-programmed (wrapped, unwrapped, liquid course) and 1 Bowie-dick test and 1 user manual mode

Full automatic operation system with working process cycle LED indicator
Easy operation with full automatic cycle by micro processor, from beginning to end cycle

Sterilization temperature 110°C to 135°C EN-13060-2 /EN -285 class B sterilization
Pre-vacuum-water filling-heating-sterilizing-ventilation-post vacuum drying-end cycle

Self-diagnostic and safety system
In case of any malfunction, it alarms and displays error codes for easy maintenance, being stop working with automatic ventilation process for safety

Specification

MODEL

LAC-5045SP

LAC-5065SP

LAC-5085SP

LAC5105SP

Sterilization Class B

Built-in pre-vacuum system & post vacuum drying system

Dimensions Outer

(WxDxH mm) Inner

770x560x900

Ø350x240

770x560x1000

Ø350x630

860x650x950

Ø450x500

860x650x1100

Ø450x630

Capacity

40â„“

60â„“

80â„“

100â„“

Reservoir Capacity

10 â„“

12 â„“

14 â„“

16 â„“

Material Exterior

             Chamber

Heavy-Duty Epoxy Resin powder coated EGI steel

Stainless steel 304 (STS 316 L option)

Heater

3kW + (Dry 1kW)*

3kW + (Dry 1kW)*

5kW + (Dry 1kW)*

5kW + (Dry 1kW)*

Sterilization Temperature

110°C - 135°C (Max)

Pressure Range

0.4 – 2.3kgf/cm²

Dry System

Post vacuum to remove steam vapor / 0-60 min

Vacuum/Pressure Gauge

-0.1 ~ 0.4Mpa (760mmHg – 4kgf/cm2)

Controller

Microprocessor PID Program Controller with LCD Monitor

Operation Cycle Mode

3 Programmed cycle, 1 Bowie-Dick test, 1 User men

Pre & Post Vacuum System

Diaphragm vacuum pump 50 LPM capacity

Display

LCD monitor (Temperature, Timer, Program cycle)

LED indicator (Water, Heat, Sterilization, Dry, End cycle)

Timer

4-90 min Sterilization & 1-90 min Dry time

PC Communication

RS-232C interface (Option)

Door

Heavy Duty Hinged up & down door

Safety Device

Over pressure safety valve, Over temperature / Over heating and over temperature protector

Door open sensing & power cut – off, Low water prevention device / Leakage & Over current circuit breaker

Standard Basket

2 ea of stainless wire basket included

Electric supply

110V, 60Hz or 220V, 50/60Hz





#Labtech, #Daihanlabtech, #Trias, #pt.trias, #alatlab, #laboratorium, #alatkesehatan, #Autoclave, #Daihan, #alatindustri,  #Steam Sterilizer,

Related product you might see:

Share this product :

 
Support : Creating Website | PT.TRIAS NATHOMI CHEMINDO | www.triasnathomichemindo.com
Copyright © 2011. PT.TRIAS NATHOMI CHEMINDO - All Rights Reserved
Template Created by Creating Website Published by www.triasnathomi.com
Proudly powered by TRANALAB