Steam Sterilizer Bench Top / Round Chamber Class B Sterilization. Pre Post Vacuum System


Feature
Sterilization temperature 110°C to 135°C EN-13060-2 class B sterilization cycle
Pre Vacuum-water filling-heating-sterilizing-ventilation-post vacuum drying-end cycle
Microprocessor PID program controller with self auto-tuned and LED display
3 pre-programmed (wrapped, unwrapped, liquid course) and 1 Bowie-dick test and 1 user manual mode
Full automatic operation system with working process cycle LED indicator
Easy operation with full automatic cycle by micro processor, from beginning to end cycle
Pre-vacuum and post vacuum Drying system
Pre-vacuum for effective air removal that results in increasing sterilization performance
Post-vacuum for drying with remaining steam removal
Self-diagnostic and mechanism
In case of any malfunction, it alarms and displays error codes for easy maintenance, being stop working with automatic ventilation process for safety purpose
Air filtration cooling system
For the process of drying cycle, 0.2µm HEPA filtered clean air flows into the chamber in order to protect air contamination and cool down below 60°C













MODEL
LAC-3011V
LAC-3021V
LAC3031V
Dimensions            Inner
(W x D x H mm)   Outer
480x720x400
Ø200x350
530x780x420
Ø250x450
650x820x500
Ø350x455
Capacity
11ℓ
22ℓ
44ℓ
Heater
1.5kW + (Dry 600W)*
2.0kW + (Dry 600W)*
3.0kW + (Dry 1kW)*
Sterilization System
Built-in pre-vacuum air removal & post vacuum drying system
Material     Exterior
                  Chamber
Epoxy powder coated electro galvanized steel
Stainless steel (STS 316 L option)
Sterilization Temperature
110°C - 135°C
Dry System
Post vacuum to remove steam vapor / 0-60 min
Vacuum/Pressure Gauge
-0.1 ~ 0.4Mpa (760mmHg – 4kgf/cm2)
Controller
Microprocessor PID Controller
Operation Cycle Mode
3 Programmed cycle, 1 Bowie-Dick test, 1 User menu
Pre & Post Vacuum System
Diaphragm vacuum pump 25 LPM capacity
Display
LED display (Temperature, Timer, Program cycle)
LED indicator (Water, Heat, Sterilization, Dry, End cycle
Timer
0-60 min Sterilization & 1-90 min Dry time
PC Communication
RS-232C interface (Option)
Door
One touch hinged door / Door inter lock system
Safety Device
Over pressure safety valve, Over temperature / Over heating protector
Door open sensing & power cut – off, Low water protection / Leakage & Over current circuit breaker
Tray
175 x 330mm
215 x 405mm
305 x 435mm
Wire tray (Standard) / Perforated tray (Option)
Electric Supply
110V, 60Hz or 220V, 50/60Hz
*Separate heater ( ) for drying process