Steam Sterilizer Class B Sterilization

 

Steam Sterilizer

Class B Sterilization. Pre Post Vacuum System

Feature

Sterilization temperature 110°C to 135°C EN-13060-2 class B sterilization cycle
Pre Vacuum-water filling-heating-sterilizing-ventilation-post vacuum drying-end cycle

Pre-vacuum and post vacuum Drying system
Pre-vacuum for effective air removal that results in increasing sterilization performance
Post-vacuum for drying with remaining steam removal

Microprocessor PID program controller with self  auto-tuned and LCD monitor
7 pre-programmed cycles as 2 wrapped, 2 unwrapped liquid, Bowie-disk and 1 user programmable.

Full automatic operation system 
Easy operation with full automatic cycle by microprocessor, from beginning to end cycle.

Self-diagnostic and Safety system
In case of any malfunction, it alarms and displays error codes for easy maintenance, being stop working with automatic ventilation process for safety purpose

Air filtration cooling system
For the process of drying cycle, 0.2µm HEPA filtered clean air flows into the chamber in order to protect air contamination and cool down below 60°C

Flushing cycle sterilization system
Can be supplied as operational order

Safe and Efficient water supply system
Automatic water supply mechanism which supplies fixed volume of water to the chamber
for maximum efficiency

Automatic and manual door lock system
When the sliding handle is entered into the locking ring, the door automatically locks after two second.
The door can be manually opened and locked using the locking wheel system.

Space saving compact design
Maximize working capacity with square chamber and minimize foot space with dedicated engineering design.

Safety Mechanism
- Over pressure release valve
- Over temperature protector with Thermostat
- Higher temp set protector by Digital high alarm limit
- Visible and Audible alarm system
- Automatic dual door locking system


Specificaion

MODEL

LAC-1011SV

LAC-1021SV

LAC-1031SV

Dimensions                   Inner

(W x D x H mm)           Outer

410 x 560 x 345

200 x 300 x 200

490 x 655 x 460

270 x 405 x 230

510 x 755 x 545

300 x 455 x 300

Capacity

12 Liter

25 Liter

40 Liter

Heater

2 kW

2.5kW

3kW

Chamber Type

Reinforced and Electro polished square chamber

Material   

Stainless Steel 304 standard (STS 316 L option)

Door Lock Mechanism

Automatic wheel inter locking with one touch sliding handle

Vacuum Pump

Built-in diaphragm vacuum pump 25 LPM capacity

Controller

Microprocessor PID Program Controller with LCD Monitor

Sterilization      Temp. Range

                           Pressure Range

                           Course

110°C - 135°C

0.4-2.3kgf/cm2

Unwrapped 1&2/ Wrapped 1&2/ Liquid/ Bowie-Dick/ User Program mode

Reservoir

6 L  stainless steel tank with top water filling inlet and silicon closer

Safety

Over pressure release valve, Over temperature

Visible and Audible alarm system, Automatic dual door locking system

Tray

180 x 260 mm

250 x 360 mm

290 x 400 mm

Wire tray (Standard) / Perforated tray (Option)

Electrical Supply

110V, 60Hz or 220V, 50/60Hz






Related product you might see:

Share this product :

 
Support : Creating Website | PT.TRIAS NATHOMI CHEMINDO | www.triasnathomichemindo.com
Copyright © 2011. PT.TRIAS NATHOMI CHEMINDO - All Rights Reserved
Template Created by Creating Website Published by www.triasnathomi.com
Proudly powered by TRANALAB