Bio Hazard Safety Cabinet – Gold Model Class Ⅱ Type A2
Feature
- HEPA Filter removes 99.99% of 0.3µm particles
- With maintenance free design and structure
- Provide high clean filter air for high performance
- UV and Fluorescent Lamp is supplied air and gas cock,
- Power consent are optional
- No required separate stand, easy to move, free from the loading
- With High Clean stainless steel interior work station and
- epoxy powder coated steel exterior for long durability
- At both sides for observation view
- 56-60 dB High efficiency sirocco fan Blower
- With LCD back light display
- Easy to replace HEPA Filter
- Built-in Mesh guard for HEPA Filter protection
- One touch open front panel for easy maintenance
- UV sterilization with on/off working timer
Specification
Model |
LCB-0103B-A2 |
LCB-0123B-A2 |
LCB-0153B-A2 |
LCB-0183B-A2 |
Dimensions Interior (WxDxHmm)Exterior Work top |
900x620x680 1050x800x1500 890 x 520 |
1200x620x680 1350x800x1500 1190x520 |
1500x620x680 1650x800x1500 1490x520 |
1800x620x680 1950x800x1500 1790x520 |
Max. door opening |
540mm |
|||
Work door opening |
200mm |
|||
Controller |
Microprocessor Controller with Air velocity
set, Low air speed alarm, Record working time and date set, Temperature
monitoring, UV & FL Lamp operation |
|||
Double Inlet Blower |
340-400 w |
440-680 w |
480-750 w |
680-800w |
Air Volume |
34 m³ /min |
50³ /min |
57³ /min |
68³ /min |
Filter Type |
Standard: ULPA U15 Filter, Aluminum fraimed
particle removal 99.9999% ISO Class 3, Class 10 Option – PTFE ULPA Filter |
|||
Air Flow Down Flow Velocity
In Flow |
Standard average 0.3 - 0.36 m/sec Standard average > 0.5m/sec |
|||
Noise Level |
Standard 56 – 60 dBA |
|||
Illumination |
FL Lamp 20 W x 1 EA |
FL Lamp 20 W x 1 EA |
FL Lamp 40 W x 1 EA |
FL Lamp 40 W x 1 EA |
UV Disinfection |
UV Lamp 15 W x 2 EA |
UV Lamp 15 W x 2 EA |
UV Lamp 15 W x 3 EA |
UV Lamp 15 W x 4 EA |
Utility Device |
Npt ¼ Air/Gas Valve, Vacuum Valve, 110V or
220 V Electric Socket (selectable), DPO test Valve |
|||
Material Interior Exterior Door |
Stainless steel grade 304 with hair lined
finish Standard-Epoxy powder coated electro galvanized steel Option – Stainless steel grade 304 Slope 7* T. 5mm tempered safety glass
sliding door |
|||
Electrical Supply |
110 V 60 Hz or 220 V 50/60 Hz descrived
order |