Feature

Pre-vacuum and post vacuum Drying system
Pre-vacuum for effective air removal that results in increasing sterilization performance.
Post-vacuum for drying with remaining system removal

Microprocessor PID program controller with self auto-tuned and LCD display
3 pre-programmed (wrapped, unwrapped, liquid course) and 1 Bowie-dick test and 1 user manual mode

Full automatic operation system with working process cycle LED indicator
Easy operation with full automatic cycle by micro processor, from beginning to end cycle

Sterilization temperature 110°C to 135°C EN-13060-2 /EN -285 class B sterilization
Pre-vacuum-water filling-heating-sterilizing-ventilation-post vacuum drying-end cycle

Self-diagnostic and safety system
In case of any malfunction, it alarms and displays error codes for easy maintenance, being stop working with automatic ventilation process for safety

Specification

MODEL

LAC-5045SP

LAC-5065SP

LAC-5085SP

LAC5105SP

Sterilization Class B

Built-in pre-vacuum system & post vacuum drying system

Dimensions  Outer

(W x D x H mm) Inner

770x560x900

Ø350x240

770x560x1000

Ø350x630

860x650x950

Ø450x500

860x650x1100

Ø450x630

Capacity

40â„“

60â„“

80â„“

100â„“

Reservoir Capacity

10 â„“

12 â„“

14 â„“

16 â„“

Material   Exterior

         Chamber

Heavy-Duty Epoxy Resin powder coated EGI steel

Stainless steel 304 (STS 316 L option)

Heater

3kW + (Dry 1kW)*

3kW + (Dry 1kW)*

5kW + (Dry 1kW)*

5kW + (Dry 1kW)*

Sterilization Temperature

110°C - 135°C (Max)

Pressure Range

0.4 – 2.3kgf/cm²

Dry System

Post vacuum to remove steam vapor / 0-60 min

Vacuum/Pressure Gauge

-0.1 ~ 0.4Mpa (760mmHg – 4kgf/cm2)

Controller

Microprocessor PID Program Controller with LCD Monitor

Operation Cycle Mode

3 Programmed cycle, 1 Bowie-Dick test, 1 User men

Pre & Post Vacuum System

Diaphragm vacuum pump 50 LPM capacity

Display

LCD monitor (Temperature, Timer, Program cycle)

LED indicator (Water, Heat, Sterilization, Dry, End cycle)

Timer

4-90 min Sterilization & 1-90 min Dry time

PC Communication

RS-232C interface (Option)

Door

Heavy Duty Hinged up & down door

Safety Device

Over pressure safety valve, Over temperature / Over heating and over temperature protector

Door open sensing & power cut – off, Low water prevention device / Leakage & Over current circuit breaker

Standard Basket

2 ea of stainless wire basket included

Electric supply

110V, 60Hz or 220V, 50/60Hz



#Labtech, #Daihanlabtech, #Trias, #pt.trias, #alatlab, #laboratorium, #alatkesehatan, #Waterbath, #Daihan, #alatindustri, #Steam Sterilizer Class B Sterilization, #Steam Sterilizer,

Related product you might see:

Share this product :

 
Support : Creating Website | PT.TRIAS NATHOMI CHEMINDO | www.triasnathomichemindo.com
Copyright © 2011. PT.TRIAS NATHOMI CHEMINDO - All Rights Reserved
Template Created by Creating Website Published by www.triasnathomi.com
Proudly powered by TRANALAB